Keep the Well and Furnace Running on Your Portable, Safely Through an Inlet

A generator inlet on the outside wall and an interlock on the main panel, so a portable can keep the well pump and furnace going in a Burns home without anyone running a cord through a window. Isaac picks the circuits with you and sizes the hookup to the generator you already own.

Snow-covered ranch land with ice-coated utility poles leaning, sagging lines and a broken crossarm down in the drifts beside a metal barn

A Plug on the Siding and a Lock on the Main

Plenty of rural households east of Cheyenne keep a portable generator in the shop for the next storm. The trouble usually starts when the power actually goes out. Someone makes up a cord with a plug on each end, pushes it into the dryer outlet, and flips a few breakers. That is a backfeed cord, and electricians refuse to install one for good reason. If the main breaker is still on, the generator pushes power back out through the meter and onto the co-op line, where a lineman restoring service expects the wire to be dead. The bare prongs on the house end are live the moment the generator starts.

The proper version has two parts. A power inlet box mounts on the outside wall near the panel, with a recessed connector that the generator cord plugs into. Inside, an interlock kit bolts onto the panel cover. It is a sliding metal plate that physically blocks the main breaker and the generator breaker from being on at the same time. To run the generator you have to shut the main off first, and the plate makes the wrong order impossible.

Interlock kits are listed for specific panel brands and models, so the first thing Isaac does on a visit is open the panel and confirm a kit exists for it. Older or discontinued panels sometimes have no matching kit, and then the conversation turns to a small manual switch instead, which our Burns transfer switch page explains. Questions about your setup? Phone (307) 757-5553 or start on the contact page.

Load

What a Portable Can Carry, Circuit by Circuit

A portable generator has a running wattage printed on its label, and every circuit you hope to power draws against it. Most portables can keep a house livable for a stretch. Few can run everything at once. So we start from the loads that matter when the line is down, whether the house sits on Main Street or out on a farm.

On a property with a well, the list begins with the well pump, since no power means no water at the tap or the stock tank. A gas furnace needs electricity only for its blower and control board, which a portable handles easily. Then a freezer or refrigerator, a couple of lighting circuits, and an outlet for phone chargers and a radio. A well pump pulls a hard surge when it starts, so we add the pieces up with that surge in mind and leave headroom for it.

The inlet gets matched to the generator’s largest outlet. A unit with a 30-amp twist-lock outlet pairs with a 30-amp inlet and cord, and a larger unit with a 50-amp outlet gets a 50-amp inlet and a heavier cord. Sizing the inlet bigger than the generator buys nothing. Our portable generator hookup page covers the service more broadly, and the Burns page lists everything else we wire out here.

Parts That Go Into a Proper Hookup

The inlet box

A weatherproof box with a hinged cover, mounted high enough that drifting snow will not bury it. We set it close to the panel to keep the wiring run short, on the side of the house where you would actually park the generator.

The interlock plate

Bolted to the panel cover and fitted to that exact panel, it keeps the main and the generator breaker from both sitting in the on position. A label on the cover spells out the switching order so anyone in the house can follow it.

A generator breaker

A two-pole breaker sized to the inlet feeds generator power into the panel. It usually lands at the top so the interlock plate can reach it, which sometimes means moving a circuit or two lower in the panel.

The cord

A generator cord with matching twist-lock ends and enough wire gauge for its length. Too long and too thin, and the voltage sags before it reaches the house. We tell you which cord fits the inlet before you buy one.

Permit and inspection

An inlet and interlock change the panel, so the work gets permitted and inspected. Inside Burns town limits that runs through the City of Burns, and on unincorporated ground through the Laramie County building department.

A breaker sized to the outlet

The generator breaker in the panel is matched to the inlet and to the outlet on the generator itself, so the cord, the inlet and the breaker all carry the same load. If the house asks for more than the portable can give, the breaker on the generator trips first.

Tell Us Which Generator Sits in the Shed

Send the make and model, or a photo of its outlet panel, along with a picture of your breaker panel. Isaac confirms an interlock fits and prices the job after he has seen the panel.

Dial (307) 757-5553 Book a Hookup Visit

Parking the Generator When the Prairie Goes Dark

Storms out here bring wind that drives snow sideways, and in a bad winter, ice that loads the lines until a pole or crossarm gives. On a long rural run from the pole to the house, that can leave a property dark until the cooperative’s crews work their way out to it. Your generator will be running outdoors through whatever weather caused the outage, so we plan where it sits on the day we install the inlet.

Carbon monoxide is the hazard that actually hurts people. A generator never runs in a garage, in a shop with the door cracked, or under an open window. Keep it well away from doors, windows and air intakes, at the distance its manual and warning label call for, with the exhaust pointed away from the house. We place the inlet so the cord reaches that spot, and we suggest a battery CO alarm indoors if you do not have one yet.

When the lights go out, the order goes like this. Turn the main breaker off. Set the generator in its spot and, with it off, plug the cord into the inlet first, then into the generator. Start it and let it settle for a minute. Slide the interlock over and switch on the generator breaker, then bring circuits on one at a time, the well pump first while nothing else is drawing. When the line comes back, reverse it: circuits off, generator breaker off, main on, then shut the generator down. We walk you through it once on the day we finish. Finished work from other jobs is in our gallery.

Questions

Hookup Questions From Burns Households

Why not just use a cord into the dryer outlet?

That cord backfeeds the house, and if the main is on, it backfeeds the co-op line too. A lineman can be hurt by power he believes is off, and the exposed plug is live while the generator runs. An inlet and interlock do the same job safely and pass inspection.

Will an interlock fit my panel?

Usually, if the panel is a common brand still in production. Each kit is made for particular panel models, so we open yours and check before pricing anything. When no listed kit exists, a small manual switch mounted beside the panel does the same job, and the visit tells you which.

Can my portable run the whole house?

Rarely. Most portables can carry the well pump, the furnace blower, a freezer, some lights and a few outlets. An electric range, water heater, dryer and air conditioner running together will overload one. We go through your loads with you and mark which breakers stay off during an outage.

What size inlet do I need?

One that matches the largest outlet on your generator. A 30-amp twist-lock outlet takes a 30-amp inlet and cord, and a 50-amp outlet takes a 50-amp inlet. Send us the model or a photo of the outlet panel and we will confirm the match before the visit.

Where should the generator sit during an outage?

Outdoors, on level ground, well away from doors, windows and vents, at the distance the manual and warning label specify. Keep it out of the garage and the shop, even with the door open. We place the inlet so the cord reaches that spot without crossing a driveway or a drift.

Does a generator inlet need a permit in Burns?

Yes. It adds a breaker and changes the panel, so it is permitted and inspected. Inside town limits the City of Burns handles it, and outside them the Laramie County building department does. We file the permit and meet the inspector, so you never have to sort out which office applies.

How is this different from a transfer switch?

An interlock uses your existing panel as the switch, and you choose circuits by flipping breakers. A transfer switch is a separate unit with its own group of selected circuits, or a whole-home switch serving a standby generator. Both keep generator power off the utility line and away from line crews.

Can I move to a standby generator later?

Yes. Plenty of owners start with a portable and an inlet, then add a standby when the budget allows. A standby runs through an automatic transfer switch and needs a gas or propane supply, so the inlet setup is usually retired at that point. We plan the panel work with that path in mind.

Getting an Inlet on the Calendar

Our shop is in Cheyenne, about twenty minutes west of Burns on Interstate 80, and we take work across Laramie County, from the town grid out to ranches along Highway 30 and County Road 212. More of the map is on the service areas page. Send your address, the generator model and a panel photo through the contact page. The easiest time to install an inlet is before the first hard storm of the season, while the generator is still sitting quietly in the shop.